The burner does not ignite after several attempts.
Possible fault Solution
Disconnect the appliance from the electrical supply for a few seconds. If the
problem persists, check if:
The burner is assembled incorrectly.
The gas valve is closed.
The burner is wet and soiled.
The flame slits are dry and
unblocked
Reassemble the burner as shown in
"Cleaning and Care - Burners".
Open the gas valve.
Clean the burners. See "Cleaning
and Care".
Dry the igniters.
The flame goes out after being lit.
Possible fault Solution
The flames are not touching the ignition safety control. Check if:
The burner is assembled incorrectly.
There is no soiling on the ignition
safety control.
Reassemble the burner as shown in
"Cleaning and Care - Burners".
See "Cleaning and Care".
The flame appears different than usual.
Possible fault Solution
The burner is assembled incorrectly. Reassemble the burner as shown in
"Cleaning and Care - Burners".
The flame goes out during operation.
Possible fault Solution
The burner is assembled incorrectly. Reassemble the burner as shown in
"Cleaning and Care - Burners".