Miele GAS KM 81-2 Instrukcje Operacyjne Strona 3

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 21
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 2
Contents
Description of the appliance 2
For your safety 5
Help protect our environment 6
Warning and Safety Instructions 7
Burner
Burner control 11
Instructions for using the gas burner 11
Power cut 12
Suitable woks, pots and pans 13
Cleaning and care 14
Problem solving guide 16
After Sales Service 17
For the installer / electrician / engineer
@>® Electrical connection 18
@>CND
Electrical connection 19
@>® Gas connection 20
@® Gas connection 22
Appliance dimensions 23
@<@> Instructions for building-in 25
(AU|)(ND
Clearance above and around the appliance 28
<@>® Installation 30
(JUSXND
Instructions for building-in 32
(CDN)(£SA) conversion to alternative types of gas 33
(AU|)(NZ) Conversion to alternative types of gas 37
For your safety
WARNING: If the information in
this manual is not followed
exactly, a fire or explosion may
result causing property damage,
personal injury or death.
Do not store or use gasoline or other
flammable vapors and liquids
in
the
vicinity of this or any other
ap-
pliance.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electrical
switch;
do not use any phone in
your building.
- Immediately call your gas sup-
plier from a neighbor's phone.
Follow the gas supplier's instruc-
tions.
- If you cannot reach your gas sup-
plier, call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Note to the installer (CDN and USA)
LEAVE THESE INSTRUCTIONS
WITH THE CONSUMER.
The appliance and its individual shutoff
valve must be disconnected from the gas
supply piping system during any pressure
testing of that system at test pressures in
excess of 1/2 psi (3.5 kPa).
The appliance must be isolated from the
gas supply piping system by closing its
individual manual shutoff valve during
any pressure testing of the gas supply
piping system at test pressures equal to
or less than 1/2 psi (3.5 kPa).
For Canada only:
The minimum supply pressure for
checking the regulator setting shall be
5 inches water column (1246 Pa),
which is
1
inch water column (249 Pa)
above the manifold pressure of 4 in-
ches water column (996 Pa).
Instructions for replacement of fixed
ori-
fices are shown on page 32. Save the
orifices removed from the appliance for
future use.
5