Safety distances to the sides of the
appliance
Ideally the appliance should be
installed with plenty of space on either
side. There may be a wall at the rear
and a tall unit or wall at one side. On
the other side, however, no unit or
divider should stand higher than the
built-in appliance (see illustrations).
Due to the high temperatures radiated
by the appliance, it is essential that a
minimum distance of 50 mm is
maintained between the worktop
cut-out and the back wall.
The minimum distance a between the
worktop cut-out and a wall or tall unit to
the right or left of it is:
40 mm for CS 1212 / CS 1212-1
CS 1221 / CS 1221-1
CS 1234 / CS 1234-1
CS 1223 / CS 1223-1
CS 1222
50 mm for CS 1112
CS 1122
CS 1134
CS 1326
CS 1327
CS 1411
100 mm for CS 1012 / CS 1012-1
150 mm for CS 1421
CS 1312
CS 1322
200 mm for CS 1034 / CS 1034-1
250 mm for CS 1011
CS 1021
Recommended
Not recommended
Not allowed