To check the first intake of air
e Retaining nut
f Air intake sleeve
Gap X must measure:
For Town Gas: 4 mm
For Natural Gas: 6 mm
For Liquid Petroleum Gas : 5 mm
If it does not:
Loosen the retaining nut, adjust the
air intake sleeve, and tighten the
retaining nut again.
Finally secure the jet against
inadvertent loosening with sealing
wax.
Reassemble the hob in the reverse
order.
The flame must not go out on the lowest
setting, or when the control is turned
quickly from a high to a low setting.
On the highest setting the flame must
have a distinctive and visible core.