Page 28 of 100
up on the coil and result in condensation dripping from your unit outside the drainage pan. THIS
IS NOT COVERED UNDER WARRANTY.
The operation of a heat pump is different than that of a conventional gas fired furnace. As a
result, you will notice differences in how the temperature is maintained. The size of the unit is
based on a “heat loss” calculation, determined by the mechanical engineer. For example, unit
size is based on your individual home’s square foot size, amount of glazing and exposure (north
or south) etc. Although it is designed to maintain temperatures under normal conditions (doors
and windows closed), you should note that under extreme weather conditions the unit may not be
able to maintain a certain set point temperature. THIS IS NORMAL FOR THIS TYPE OF
SYSTEM, AND DOES NOT MEAN YOUR UNIT IS NOT WORKING CORRECTLY.
In simplified terms, your unit operates as follows. In winter, when you require heat, it extracts heat
from the closed loop geothermal system water that is piped throughout the building. It then injects
that heat, by way of a fan coil, into your unit. In summer, the reverse happens. It extracts the
heat the unit absorbs from the return air, and injects that heat into the water to be piped away
from your unit. This type of system requires more time than a conventional gas fired furnace to
increase or decrease temperature, and will function better if you leave the thermostat set at a
certain temperature. If you set the temperature significantly lower at night, it may take a bit longer
to regain the temperature in the morning. THIS IS NORMAL.
It is also important to know that your unit contains both a compressor and a fan. YOUR UNIT
WILL MAKE A CERTAIN AMOUNT OF NOISE UNDER NORMAL OPERATION. SILENT
OPERATION IS NOT REALISTIC. Please expect a level of noise similar to the noise you would
expect from a conventional furnace.
The electric panel provides shutoff breaker(s) for (among other things) the geothermal heating
and cooling system. The electric panel is normally located in the 2
nd
bedroom, the master
bedroom or the storage room, behind the applicable room door. Please take the time to note its
location.
Thermostat
Your thermostat is a Honeywell TH2110D. The operating manual was included in your Welcome
Package.
Your thermostat is programmable. Please familiarize yourself with the operation and
programming of your thermostat, as warranty does not cover improper operation or improper
setting of your thermostat. If you require further assistance please call Honeywell’s customer
service at 1 800 468-1502.
Manufacturer’s Literature
The products installed in your home come with manufacturers “Use and Care Guides” and
“Warranties” – please take the time to read them. These guides and warranties were provided to
you on your possession date. They were included in your Welcome Package. The information
contained in the manufacturer’s literature will not be repeated here.
We make every effort to keep the information in this Manual current. If any detail in our
Manual conflicts with the manufacturer's information or recommendations, follow the
manufacturer's recommendations.
Komentarze do niniejszej Instrukcji